On Thu, 28 Aug 2014 09:59:35 -0700
Jason Ekstrand wrote:
> Really, do we need a whole 30 seconds? You can easily do enough
> interaction to crash something in 30 seconds. Other than that, this looks
> fine.
> Reviewed-by: Jason Ekstrand
The timeout starts to run on shell module load, and I wa
Really, do we need a whole 30 seconds? You can easily do enough
interaction to crash something in 30 seconds. Other than that, this looks
fine.
Reviewed-by: Jason Ekstrand
On Thu, Aug 28, 2014 at 1:48 AM, Pekka Paalanen wrote:
> From: Pekka Paalanen
>
> If weston-desktop-shell dies soon aft
From: Pekka Paalanen
If weston-desktop-shell dies soon after launch, or maybe cannot be
executed at all, let weston exit rather than letting the user stare at a
black screen.
But, do not exit weston, if weston-desktop-shell dies later, as the user
may already have apps open, and those apps would