Increasing the size of the allocated memory worked. Thank you!
On Jun 23, 2023 08:20, Joel Sherrill wrote:
Hi
The message "sec1: (tsec ethernet) Your application has not enough mbuf
clusters configured for this driver." would normally indicate that you don't
have enough mbuf memory configured
For the Legacy stack you have to define MBUFS in rtems_bsdnet_config.
Example from EPICS:
os/CONFIG.Common.RTEMS-mvme3100:ARCH_DEP_CFLAGS +=
-DRTEMS_NETWORK_CONFIG_MBUF_SPACE=2048
struct rtems_bsdnet_config rtems_bsdnet_config = {
FIRST_DRIVER_CONFIG, /* Link to next interface */
MY
Hi
The message "sec1: (tsec ethernet) Your application has not enough mbuf
clusters configured for this driver." would normally indicate that you
don't have enough mbuf memory configured. See
https://git.rtems.org/network-demos/tree/networkconfig-mpc8313erdb.h
around line 88 for the parameters