Hi Claudio,
> Yes, since you disconnected the link between the carp interfaces without
> dropping their physical connections both will become MASTER.
> This normaly results in havoc since bad luck will flow all traffic to the
> wrong box. This is the typical problem with too much redundancy (the
>
On Thu, Aug 19, 2010 at 01:49:17PM -0400, Peter Bisroev wrote:
> Hi All,
>
> I have tried searching the mailing lists but did not seem to find the
> answer to the issue that I am seeing. I apologize for the long email,
> but more info is better than less :)
>
...
> For the tests performed all s
Hi All,
I have tried searching the mailing lists but did not seem to find the
answer to the issue that I am seeing. I apologize for the long email,
but more info is better than less :)
For testing I have two OpenBSD 4.7-stable firewalls, and each has a
PCIe quad port Intel PRO/1000 QP (82571EB).