On Mon, Mar 14, 2011 at 9:10 PM, Guy Harris wrote:
>
> On Mar 14, 2011, at 5:14 AM, M.Baris Demiray wrote:
>
>> Indeed, may be you could also add (along with the link to the old
>> unclassified version) that new versions of STANAG 5066 haven't
>> introduced any
On Sun, Mar 13, 2011 at 8:11 PM, Guy Harris wrote:
>
> On Feb 17, 2011, at 11:41 PM, M.Baris Demiray wrote:
>
>>> Do they begin with the 16-bit synchronization sequence, or is that stripped
>>> off, so that they begin with the header field? Do data PDUs include the
Hello,
On Thu, Feb 10, 2011 at 6:46 PM, Guy Harris wrote:
>
> On Feb 6, 2011, at 10:17 PM, M.Baris Demiray wrote:
>
>> Unfortunately no, there is not. As in SIS Layer dissector this is also
>> a part of a standard which is available only to NATO member states
>
> H
Hello,
On Mon, Feb 7, 2011 at 12:21 AM, Guy Harris wrote:
>
> On Feb 4, 2011, at 12:25 AM, M.Baris Demiray wrote:
>
>> In fact this is not what STANAG 5066 Annex H "Implementation Guide and
>> Notes" section suggests. According to this section and the tests h
On Thu, Feb 3, 2011 at 9:54 PM, Guy Harris wrote:
>
> On Feb 3, 2011, at 8:47 AM, M.Baris Demiray wrote:
>
>> Hello again,
>>
>> I have solved almost all the problems that I mentioned below and now I
>> am sure that I should ask for a new DLT value for STAN
Hello,
On Thu, Feb 3, 2011 at 9:51 PM, Guy Harris wrote:
>
> On Jan 19, 2011, at 1:02 AM, M.Baris Demiray wrote:
>
>> First of all, we're developing radio communication software,
>> particularly STANAG 5066. Alongside the serial interface for the modem
>> interfa
r the interface between STANAG 5066 and HF modem as
well. What else should I provide regarding this protocol to ask for a
DLT value?
Cheers,
[1] http://en.wikipedia.org/wiki/STANAG_5066
[2] http://wiki.wireshark.org/STANAG_5066
On Wed, Jan 19, 2011 at 9:02 AM, M.Baris Demiray wrote:
> Hello,
&g
Hello,
I've a couple of questions regarding dissector development and DLT_
values and I hope I know enough to express myself.
First of all, we're developing radio communication software,
particularly STANAG 5066. Alongside the serial interface for the modem
interface our implementation also has a