Re: USR Courier I-modem

1998-03-13 Thread Michael L. Collins
> From: Michael L. Collins <[EMAIL PROTECTED]> > > -- > > From: Philip Hands <[EMAIL PROTECTED]> > > > > You have to be fairly patient with I-modems, because they take a long > time to > > reset compared with other modems (in some of the versions of the code > this was > > bad enough

Re: USR Courier I-modem

1998-03-13 Thread Michael L. Collins
> From: Michael L. Collins <[EMAIL PROTECTED]> > > When I use minicom the modem seems > to work OK. That is, I can send AT commands > and get OK responses. But when I attempt > the same commands in the chatscript, > the script never recieves the "OK" response > from the modem. pppd exits wi

Re: USR Courier I-modem

1998-03-13 Thread Michael L. Collins
> From: Angus Black <[EMAIL PROTECTED]> > Michael, > Try the following init string, AT&F*V2=5, works for us. > > Regards > > Angus Black > > Hiway Communications > I am using the *V2=5 but &F1. Just &F is not listed as an option. Here is my complete init string: AT&F1&C1&D2&K1&H1&R2

USR Courier I-modem

1998-03-13 Thread Michael L. Collins
Have you gotten one of these USR Courier I-modems to work? When I use minicom the modem seems to work OK. That is, I can send AT commands and get OK responses. But when I attempt the same commands in the chatscript, the script never recieves the "OK" response from the modem. pppd exits with