> From: Michael L. Collins <[EMAIL PROTECTED]>
>
> --
> > From: Philip Hands <[EMAIL PROTECTED]>
> >
> > You have to be fairly patient with I-modems, because they take a long
> time to
> > reset compared with other modems (in some of the versions of the code
> this was
> > bad enough
> From: Michael L. Collins <[EMAIL PROTECTED]>
>
> When I use minicom the modem seems
> to work OK. That is, I can send AT commands
> and get OK responses. But when I attempt
> the same commands in the chatscript,
> the script never recieves the "OK" response
> from the modem. pppd exits wi
> From: Angus Black <[EMAIL PROTECTED]>
> Michael,
> Try the following init string, AT&F*V2=5, works for us.
>
> Regards
>
> Angus Black
>
> Hiway Communications
>
I am using the *V2=5 but &F1.
Just &F is not listed as an option.
Here is my complete init string:
AT&F1&C1&D2&K1&H1&R2
Have you gotten one of these
USR Courier I-modems to work?
When I use minicom the modem seems
to work OK. That is, I can send AT commands
and get OK responses. But when I attempt
the same commands in the chatscript,
the script never recieves the "OK" response
from the modem. pppd exits with