sebas abandoned this revision.
sebas added a comment.
Okay, thanks David.
REPOSITORY
R127 KWayland
REVISION DETAIL
https://phabricator.kde.org/D5872
To: sebas, #plasma, hein, davidedmundson
Cc: graesslin, bshah, davidedmundson, plasma-devel, #frameworks, ZrenBot,
spstarr, progwolff, les
davidedmundson added a comment.
I merged a different thing that Martin was happy wtih. This is closable.
REPOSITORY
R127 KWayland
REVISION DETAIL
https://phabricator.kde.org/D5872
To: sebas, #plasma, hein, davidedmundson
Cc: graesslin, bshah, davidedmundson, plasma-devel, #frameworks, Zr
graesslin added a comment.
In https://phabricator.kde.org/D5872#109962, @hein wrote:
> I'm fine with no change signal, but heads-up that libtaskmanager has code
connecting to it, so if you remove it from kwayland please also adapt
plasma-workspace or the build breaks.
I highly su
hein added a comment.
No, I don't. libtaskmanager doesn't use PlasmaWindowModel, it uses
PlasmaWindow.
REPOSITORY
R127 KWayland
REVISION DETAIL
https://phabricator.kde.org/D5872
To: sebas, #plasma, hein, davidedmundson
Cc: graesslin, bshah, davidedmundson, plasma-devel, #frameworks, Zre
davidedmundson added a comment.
No you don't.
You connect via QAIM;: dataChanged which is still there.
REPOSITORY
R127 KWayland
REVISION DETAIL
https://phabricator.kde.org/D5872
To: sebas, #plasma, hein, davidedmundson
Cc: graesslin, bshah, davidedmundson, plasma-devel, #frameworks, Zr
hein added a comment.
I'm fine with no change signal, but heads-up that libtaskmanager has code
connecting to it, so if you remove it from kwayland please also adapt
plasma-workspace or the build breaks.
REPOSITORY
R127 KWayland
REVISION DETAIL
https://phabricator.kde.org/D5872
To: seb
graesslin added a comment.
like David explained: we don't need the change signal and IMHO we shouldn't
expose "wrong API". I consider having a changed signal for a PID wrong API as
it indicates that the PID could change. But it won't ever change, so we
shouldn't expose it. I know that all ot
davidedmundson requested changes to this revision.
davidedmundson added a comment.
This revision now requires changes to proceed.
> it can still be set after being initially 0. In fact, it has to be.
Not at the time the client sees it.
see initialStateCallback which is important.
sebas added a comment.
Possibly, in this case, I disagree. The pid is initially unknown set to in
the client, and can change afterwards. In reality, the pid of the window
doesn't change, but it can still be set after being initially 0. In fact, it
has to be.
In the end, I don't care muc
sebas requested review of this revision.
REPOSITORY
R127 KWayland
REVISION DETAIL
https://phabricator.kde.org/D5872
To: sebas, #plasma, hein, davidedmundson
Cc: bshah, davidedmundson, plasma-devel, #frameworks, ZrenBot, spstarr,
progwolff, lesliezhai, ali-mohamed, jensreuterberg, abetts, el
bshah added a comment.
In https://phabricator.kde.org/D5872#109874, @sebas wrote:
> What's d581?
I think he meant https://phabricator.kde.org/D5851
REPOSITORY
R127 KWayland
REVISION DETAIL
https://phabricator.kde.org/D5872
To: sebas, #plasma, hein, davidedmundson
Cc: bshah,
sebas added a comment.
What's d581?
REPOSITORY
R127 KWayland
REVISION DETAIL
https://phabricator.kde.org/D5872
To: sebas, #plasma, hein, davidedmundson
Cc: davidedmundson, plasma-devel, #frameworks, ZrenBot, spstarr, progwolff,
lesliezhai, ali-mohamed, jensreuterberg, abetts, eliasp, se
davidedmundson requested changes to this revision.
davidedmundson added a comment.
This revision now requires changes to proceed.
See d581
REPOSITORY
R127 KWayland
REVISION DETAIL
https://phabricator.kde.org/D5872
To: sebas, #plasma, hein, davidedmundson
Cc: davidedmundson, plasma-devel,
sebas created this revision.
Restricted Application added projects: Plasma on Wayland, Frameworks.
Restricted Application added subscribers: Frameworks, plasma-devel.
REVISION SUMMARY
Eike removed this, but I'm not sure why. All other roles trigger
datachanged, so I don't see why pid shouldn't
14 matches