From: Hoang Le
Date: Thu, 6 Dec 2018 09:00:09 +0700
> When setting LINK tolerance, node timer interval will be calculated
> base on the LINK with lowest tolerance.
>
> But when calculated, the old node timer interval only updated if current
> setting value (tolerance/4) less than old ones regar
When setting LINK tolerance, node timer interval will be calculated
base on the LINK with lowest tolerance.
But when calculated, the old node timer interval only updated if current
setting value (tolerance/4) less than old ones regardless of number of
links as well as links' lowest tolerance value