YES !!!
At last, I found how to do, I reduced MAX_PLAYOUT_BUFFER_DURATION from 0.1 to
0.001 second and it works fine.
Actually, the value at 0.1 allows to have a gap about 100ms between the
estimated rate and the output rate, it is too high for the DTE-3114.
With this value at 0.001, the computa
After some new tests, if I modify NEW_DURATION_WEIGHT, TIME_ADJUSTMENT_FACTOR
or PCR_PERIOD_VARIATION_RATIO, nothing becomes right but I defined DEBUG_PCR
and when macroblocks happen, I can see a variation on the estimation of the
PCR. Most of the time, it is at 162 and regularly it decreases at
At last, I have an answer from dektec supprt.
Actually, it's clear than the .ts file is correct and the PCR is perfect, the
outgoing RTP packet are also perfect but there is a very small mismatching
between the bandwidth and the PCR during approximativelly 75 seconds afterwhat
the bandwidth and
Hi Ross,
We are checking for audio stream support with Live555 and we would like to
know if we can stream the following codec
AAC-LC and/or AAC-HE through the library.
Thanks,
Sagi
-Original Message-
From: live-devel-boun...@ns.live555.com
[mailto:live-devel-boun...@ns.live555.com] On
I'm using windows because we also use several application all done on windows
!!!
I fully agree with you about the weakness of this OS but it's like that and I
don't really have choice.
On the other hand, I have the chance to be able to compare 2 kind of streaming
and I tried to reproduce the