Bug#538304: insserv: start and stop in same runlevel

2019-04-14 Thread Dmitry Bogatov
control: tags -1 +fixed-upstream [2019-04-11 17:50] Jesse Smith > > part text/plain1086 > On 4/11/19 7:43 AM, Dmitry Bogatov wrote: > > [2019-01-24 19:42] Jesse Smith > >> I'm looking into this bug in insserv and want to make sure I'm > >> understanding the issue correctl

Bug#538304: insserv: start and stop in same runlevel

2019-04-11 Thread Jesse Smith
On 4/11/19 7:43 AM, Dmitry Bogatov wrote: > [2019-01-24 19:42] Jesse Smith >> I'm looking into this bug in insserv and want to make sure I'm >> understanding the issue correctly. As I read it, the problem is that if >> the user specifies the same runlevel in both the Default-Start and >> Default-S

Bug#538304: insserv: start and stop in same runlevel

2019-04-11 Thread Dmitry Bogatov
[2019-01-24 19:42] Jesse Smith > I'm looking into this bug in insserv and want to make sure I'm > understanding the issue correctly. As I read it, the problem is that if > the user specifies the same runlevel in both the Default-Start and > Default-Stop fields, insserv will set up the "Stop" sym