Bug#1010001: libbiosig3: incorrect sample rate when reading IBW files

2022-12-03 Thread Andreas Tille
Control: tags -1 wontfix As mentioned in my previous response we can not fix issues in stable. Leaving this bug open anyway to document the issue. There was no request for an upload to backports yet. Kind regards, Andreas. -- http://fam-tille.de

Bug#1010001: libbiosig3: incorrect sample rate when reading IBW files

2022-04-25 Thread Andreas Tille
Hi Alois, thank you for your bug report with patch. Unfortunately we can only fix RC bugs in Debian stable. I wonder whether you would consider it a sensible solution to backport biosig 2.3.3 to debian-backports? Kind regards Andreas. Am Fri, Apr 22, 2022 at 08:44:08AM +0200 schrieb Aloi

Bug#1010001: libbiosig3: incorrect sample rate when reading IBW files

2022-04-21 Thread Alois Schlögl
Package: libbiosig3 Version: 2.1.2-4 Severity: normal Tags: patch X-Debbugs-Cc: alois.schlo...@gmail.com Dear Maintainer, libbiosig supports reading many different data formats, including the IgorBinaryWaveform (IBW) format. When reading this data, an incorrect sampling rate (e.g. 25 Hz i