Dear Zahid, There is no screenshot so I'm guessing that the problem is a CUDA memory error. If you use the command line tool rtkfdk, you should first make sure that you use the --lowmem option to stream the projection images. If it is no sufficient, you can split your volume using the --divisions. The corresponding C++ code can be found in rtkfdk.cxx. Is Panacea Medical using RTK? We are happy to advertise the use of RTK on our case studies webpage <http://openrtk.org/RTK/project/casestudies.html>. Simon
On Sat, Oct 15, 2016 at 11:12 AM, Zahid Hasan Ansari < [email protected]> wrote: > > > Dear Sir\Madam, > > > > I am unable to do 1024x1024x1024 reconstruction using RTK > > CudaFDKConeBeamReconstructionFilter. Please check the screen shoot of > the > > same. > > > > I am using the following items given below. > > > > 1. RTK - RTK version 1.3 > > 2. ITK - ITK version 4.7 > > 3. Visual Studio 2013 win 64-bit console application > > 4. GeForce GTX TITAN X GPU. > > 5. CUDA 7. > > 6. CMake version 3.4.3. > > 7. Windows 7 64-bit OS. > > > > Please provide the solution of this and let me know if any > > other clarification is required. > > > > > > > > Thanks & Regards > > > > Zahid Hasan Ansari > > Senior Design Engineer > > Mobile No. +91-9738379729 > > > > Panacea Medical Technologies Pvt. Ltd. > > Head Office: Plot #119, GF, Envision Technology Center, EPIP Area Phase > 1, > > Whitefield, Bangalore - 560 066, Karnataka, INDIA > > Manufacturing Unit: Plot #87 A, Phase -II, Malur KIADB Industrial Area, > > Malur - 563130. Kolar District. INDIA. > > Tel : +91 80 4242 8700 / 2845 4785 | Fax : + 91 42428710 | Url : > > http://www.panaceamedical.com > > Bangalore - India. > > ________________________________________ > PANACEA MEDICAL TECHNOLOGIES PVT. LTD. > Head Office: Plot #119, GF, Envision Technology Center, EPIP Area Phase > 1, Whitefield, Bangalore - 560 066, Karnataka, INDIA > Manufacturing Unit: Plot #87 A, Phase -II, Malur KIADB Industrial Area, > Malur - 563130. Kolar District. INDIA. > > Tel : +91 80 4242 8700 / 2845 4785 > Fax : + 91 80 42428710 > Url : http://www.panaceamedical.com > ____________________________________________________________ > ________________ > PMT EMAIL DISCLAIMER: > > This email and any files transmitted with it are confidential and intended > solely for the use of the individual or entity to whom they are addressed. > If you have received this email in error please notify the system manager. > Please note that any views or opinions presented in this email are solely > those of the author and do not necessarily represent those of the company. > Finally, the recipient should check this email and any attachments for the > presence of viruses. The company accepts no liability for any damage > caused by any virus transmitted by this email. > > > _______________________________________________ > Rtk-users mailing list > [email protected] > http://public.kitware.com/mailman/listinfo/rtk-users >
_______________________________________________ Rtk-users mailing list [email protected] http://public.kitware.com/mailman/listinfo/rtk-users