No I can't. In my first posting I list why. The firmware for the Del PERC cards only allows "spanning" (striping across other RAID arrays) across 8 devices. We want to span/stripe across 12 so hardware RAID10 is out of the question.
BTW, we had the same disk subsystem and RAID configuration on an older box and had no issues with I/O performance. The current system is running Red Hat 2.4.18-17.7.xbigmem; the old system was running vanilla 2.4.18 with LVM 1.0.3 and VFS lock patches. -----Original Message----- From: nate [mailto:[EMAIL PROTECTED]] Sent: Friday, December 06, 2002 10:56 PM To: [EMAIL PROTECTED] Subject: Re: Poor performance, high disk queue on software RAID partition Rechenberg, Andrew said: > > Sorry for the cross-post, but I wanted to hit all areas which may be a > contributing factor to my issue. sounds like your situation may be related to this: http://kt.zork.net/kernel-traffic/kt20021202_194.html#6 no way you can do hardware raid10? one thing to try would be to run it without software raid and see what happens. I've never heard of someone running software raid ontop of hardware raid.. interesting nate -- redhat-list mailing list unsubscribe mailto:[EMAIL PROTECTED]?subject=unsubscribe https://listman.redhat.com/mailman/listinfo/redhat-list -- redhat-list mailing list unsubscribe mailto:[EMAIL PROTECTED]?subject=unsubscribe https://listman.redhat.com/mailman/listinfo/redhat-list