FYI...
This is also happening to me.. I am using a MySQL backend for accountig and
authentication

---
Edgar R Gutierrez
Head of Technical Operations
Impact Information Systems
Contact Number:+632 7296826
Mobile: +63917 9802340

----- Original Message -----
From: Joshua M. Thompson <[EMAIL PROTECTED]>
To: <[EMAIL PROTECTED]>
Sent: Tuesday, July 04, 2000 5:22 AM
Subject: Re: (RADIATOR) Problem with Simultaneous-Use and proxying


> On Mon, 3 Jul 2000, Hugh Irvine wrote:
>
> > Radiator should only try to directly query the NAS if you are enforcing
strict
> > simultaneous use with a NasType set for your Client clauses. If you
don't have
> > a NasType set, it won't be queried.
>
> The funny part here is it's querying NASes that _aren't_ in my client
> list. It's querying a NAS to which one of my users is logged in but that
> NAS talks is talking to a RADIUS server one or more "proxy hops" away.
>
> > And when you mention stuck sessions, are these really stuck on the NAS,
or are
> > they simply remnants in the session database?
>
> They're not stuck on the NASes, just in my session database. It primarily
> seems to be happening to users who come in to the numbers where the
> authentication goes through another RADIUS server that's proxying from
> me. I see very few happening on my numbers,
>
> > It would be useful to see a copy of your configuration file (no secrets)
> > together with an example trace 4 debug showing what is happening.
>
> I'l have to catch the trace sometime today, but I've started by attaching
> my radius.cfg. Beware, it's big and hairy, mostly owing to having to sort
> out classes of service based only on packet contents (such as
> distinguishing Merit calls from everything else by looking for a
> Huntgroup-Name attribute). The MARVIN stuff is a custom auth module that
> talks to our proprietary MySQL billing and provisioning system. It
> shouldn't be causing any problems since it's only doing authentications
> and not logging or session management.
>
> > BTW - the latest version of Radiator is 2.16.1.
>
> Yep I noticed that after I sent my letter...I've been neglecting to keep
> up with the list for the past three or four months. I'll have to install a
> test copy around here and validate the MARVIN module with it so I can
> deploy it.
>
> --
> Senior Systems Engineer      | "Where are we going, and what am I doing in
> BigNet, Inc.                 |  this handbasket?"
> Phone: 248-771-1261          |      - Paraphrased from various people's
.sigs