On Sun, 22 Aug 2021 at 04:55, Richard Henderson
<richard.hender...@linaro.org> wrote:
>
> Use the new functions instead of setting up a target_siginfo_t
> and calling queue_signal.
>
> The user-only version of ppc_cpu_tlb_fill does not distinguish
> between the various hw codes.  Drop all of that and just use
> the new force_sigsegv_for_addr function.  The fault address for
> POWERPC_EXCP_ISI is nip exactly, not nip - 4.
>
> Signed-off-by: Richard Henderson <richard.hender...@linaro.org>

Reviewed-by: Peter Maydell <peter.mayd...@linaro.org>

thanks
-- PMM