Hi, Richard.
On 07/23/2021 09:45 AM, Richard Henderson wrote:
>> +/* Fixed point load/store instruction translation */
>> +static bool trans_ld_b(DisasContext *ctx, arg_ld_b *a)
>> +{
>> + TCGv t0;
>> + TCGv Rd = cpu_gpr[a->rd];
>> + int mem_idx = ctx->mem_idx;
>> +
>> + if (a->rd == 0) {
>> + /* Nop */
>> + return true;
>> + }
>
> A load into the zero register is not a nop. It is a load with the result
> discarded. One should still fault if the load is to an invalid address.
>
> You should be using a common routine, passing in the MO_* operand.
>
OK.
>> +#define ASRTGT \
>> + do { \
>> + TCGv t1 = get_gpr(a->rj); \
>> + TCGv t2 = get_gpr(a->rk); \
>> + gen_helper_asrtgt_d(cpu_env, t1, t2); \
>> + } while (0)
>> +
>> +#define ASRTLE \
>> + do { \
>> + TCGv t1 = get_gpr(a->rj); \
>> + TCGv t2 = get_gpr(a->rk); \
>> + gen_helper_asrtle_d(cpu_env, t1, t2); \
>> + } while (0)
>> +
>> +#define DECL_ARG(name) \
>> + arg_ ## name arg = { \
>> + .rd = a->rd, \
>> + .rj = a->rj, \
>> + .rk = a->rk, \
>> + };
>> +
>> +static bool trans_ldgt_b(DisasContext *ctx, arg_ldgt_b *a)
>> +{
>> + ASRTGT;
>> + DECL_ARG(ldx_b)
>> + trans_ldx_b(ctx, &arg);
>> + return true;
>> +}
>
> Use of a common routine would avoid the macro ugliness.
OK.
Thanks you kindly help.