On 2/19/21 6:45 AM, Peter Maydell wrote:
The SSE-300 is mostly the same as the SSE-200, but it has moved some
of the devices in the memory map and uses different device types in
some cases. To accommodate this, add a framework where the placement
and wiring of some devices can be specified in a data table.
This commit adds the framework for this data-driven device placement,
and makes the CMSDK APB timer devices use it. Subsequent commits
will convert the other devices which differ between SSE-200 and
SSE-300.
Signed-off-by: Peter Maydell<[email protected]>
---
Reviewed-by: Richard Henderson <[email protected]>