On 2/19/21 6:45 AM, Peter Maydell wrote:
The SSE-200 and SSE-300 have different PID register values from the
IoTKit for the sysctl register block.  We incorrectly implemented the
SSE-200 with the same PID values as IoTKit.  Fix the SSE-200 bug and
report these register values for SSE-300.

Signed-off-by: Peter Maydell<[email protected]>
---

Reviewed-by: Richard Henderson <[email protected]>