On 2/19/21 6:45 AM, Peter Maydell wrote:
The version of the SYSINFO Register Block in the SSE-300 has
different CIDR/PIDR register values to the SSE-200; pass in
the sse-version property and use it to select the correct
ID register values.

Signed-off-by: Peter Maydell<[email protected]>
---
  include/hw/misc/iotkit-sysinfo.h |  1 +
  hw/arm/armsse.c                  |  2 ++
  hw/misc/iotkit-sysinfo.c         | 29 +++++++++++++++++++++++++++--
  3 files changed, 30 insertions(+), 2 deletions(-)

Reviewed-by: Richard Henderson <[email protected]>

r~

Reply via email to