From: John Snow <[email protected]>

Three seconds is hardcoded. Use it as a default parameter instead, and use that
value for both waits that may occur in the function.

Signed-off-by: John Snow <[email protected]>
Reviewed-by: Philippe Mathieu-Daudé <[email protected]>
Reviewed-by: Cleber Rosa <[email protected]>
Message-Id: <[email protected]>
Signed-off-by: Philippe Mathieu-Daudé <[email protected]>
---
 python/qemu/machine.py | 8 +++++---
 1 file changed, 5 insertions(+), 3 deletions(-)

diff --git a/python/qemu/machine.py b/python/qemu/machine.py
index c28957ee82..e825f0bdc6 100644
--- a/python/qemu/machine.py
+++ b/python/qemu/machine.py
@@ -393,7 +393,9 @@ def wait(self):
         self._popen.wait()
         self._post_shutdown()
 
-    def shutdown(self, has_quit=False, hard=False):
+    def shutdown(self, has_quit: bool = False,
+                 hard: bool = False,
+                 timeout: Optional[int] = 3) -> None:
         """
         Terminate the VM and clean up
         """
@@ -409,10 +411,10 @@ def shutdown(self, has_quit=False, hard=False):
                 try:
                     if not has_quit:
                         self._qmp.cmd('quit')
-                    self._popen.wait(timeout=3)
+                    self._popen.wait(timeout=timeout)
                 except:
                     self._popen.kill()
-            self._popen.wait()
+            self._popen.wait(timeout=timeout)
 
         self._post_shutdown()
 
-- 
2.21.3