** Changed in: qemu
       Status: New => Invalid

-- 
You received this bug notification because you are a member of qemu-
devel-ml, which is subscribed to QEMU.
https://bugs.launchpad.net/bugs/1480562

Title:
  register values in sp804 timer

Status in QEMU:
  Invalid

Bug description:
  In the arm_timer.c, when first reading the load register,  I got 0.

  ...
  case 0: /* TimerLoad */
  ...

  According to the specification at 
http://infocenter.arm.com/help/index.jsp?topic=/com.arm.doc.ddi0271d/index.html,
 
  "The minimum valid value for TimerXLoad is 1".  Is the initial value supposed 
to be 0xffffffff?

  
  When the 5th and 7th bit in Control Register are set, RIS and MIS remain 0. 
But should they be enabled (i.e., 0x1 and 0x1) as both interrupt and timer 
module are set. 

  Thanks.

To manage notifications about this bug go to:
https://bugs.launchpad.net/qemu/+bug/1480562/+subscriptions

Reply via email to