If tests use a TCP based monitor socket, the connection will
go into a TIMED_WAIT state when the test exits. This will
randomly prevent the test from being re-run without a certain
time period. Set the SO_REUSEADDR flag on the socket to ensure
we can immediately re-run the tests
---
scripts/qmp/qmp.py | 1 +
1 file changed, 1 insertion(+)
diff --git a/scripts/qmp/qmp.py b/scripts/qmp/qmp.py
index 2d0d926..62d3651 100644
--- a/scripts/qmp/qmp.py
+++ b/scripts/qmp/qmp.py
@@ -43,6 +43,7 @@ class QEMUMonitorProtocol:
self._debug = debug
self.__sock = self.__get_sock()
if server:
+ self.__sock.setsockopt(socket.SOL_SOCKET, socket.SO_REUSEADDR, 1)
self.__sock.bind(self.__address)
self.__sock.listen(1)
--
2.5.5