From: Alistair Francis <[email protected]>

Remove the hardcoded values from the machine specific reset
function, as the same values are already set in the standard
MicroBlaze reset.

This also allows the entire reset function to be deleted, as
PVR registers are now preserved on reset.

Signed-off-by: Alistair Francis <[email protected]>
Reviewed-by: Edgar E. Iglesias <[email protected]>
Reviewed-by: Peter Crosthwaite <[email protected]>
Signed-off-by: Edgar E. Iglesias <[email protected]>
---
 hw/microblaze/petalogix_s3adsp1800_mmu.c | 9 +--------
 1 file changed, 1 insertion(+), 8 deletions(-)

diff --git a/hw/microblaze/petalogix_s3adsp1800_mmu.c 
b/hw/microblaze/petalogix_s3adsp1800_mmu.c
index 4dbbd1e..0c2140c 100644
--- a/hw/microblaze/petalogix_s3adsp1800_mmu.c
+++ b/hw/microblaze/petalogix_s3adsp1800_mmu.c
@@ -51,13 +51,6 @@
 #define ETHLITE_IRQ         1
 #define UARTLITE_IRQ        3
 
-static void machine_cpu_reset(MicroBlazeCPU *cpu)
-{
-    CPUMBState *env = &cpu->env;
-
-    env->pvr.regs[10] = 0x0c000000; /* spartan 3a dsp family.  */
-}
-
 static void
 petalogix_s3adsp1800_init(MachineState *machine)
 {
@@ -128,7 +121,7 @@ petalogix_s3adsp1800_init(MachineState *machine)
     microblaze_load_kernel(cpu, ddr_base, ram_size,
                            machine->initrd_filename,
                            BINARY_DEVICE_TREE_FILE,
-                           machine_cpu_reset);
+                           NULL);
 }
 
 static QEMUMachine petalogix_s3adsp1800_machine = {
-- 
1.9.1