29.06.13 18:16, Nadeem Vawda написав(ла):
I ran into the same problem in the _lzma module. My solution was to define a custom converter that does an explicit check before returning the value (see http://hg.python.org/cpython/file/default/Modules/_lzmamodule.c#l134).
Definitely Argument Clinic should use converters for unsigned integers without wraparound by default.
_______________________________________________ Python-Dev mailing list Python-Dev@python.org http://mail.python.org/mailman/listinfo/python-dev Unsubscribe: http://mail.python.org/mailman/options/python-dev/archive%40mail-archive.com