Richard Oudkerk added the comment:
According to Alan Cox
It's a design decision and a huge performance win. It's one of the areas
where POSIX read in its strictest form cripples your performance.
See https://lkml.org/lkml/2011/6/18/103
> (For write ready, you can obviously have "spurious" notifications if
> you try to write more than what is available in the output socket
> buffer).
Wouldn't you just get a partial write (assuming an AF_INET, SOCK_STREAM socket)?
----------