On 30.01.2018 08:13, Georg Chini wrote:
On 30.01.2018 03:08, NicoHood wrote:
On 01/29/2018 07:48 PM, Georg Chini wrote:
On 29.01.2018 19:39, NicoHood wrote:
On 01/29/2018 07:19 PM, Georg Chini wrote:
On 29.01.2018 18:46, Nico wrote:
On 01/29/2018 03:52 PM, NicoHood wrote:
On 01/29/2018 03:29 PM, Georg Chini wrote:
On 29.01.2018 14:44, NicoHood wrote:
On 01/29/2018 01:39 PM, Georg Chini wrote:
On 29.01.2018 12:52, Nico wrote:
If the sound card supports it, PA will always use either the default
or the alternative sample rate, whatever fits the current stream
better, unless there is already a stream running on the card.
So it should be enough to run module-loopback with rate=48000.
Don't forget to change the values in daemon.conf back to their
original values before you try it.
Setting the rate for the loopback module does not give a positive
result. Setting the sample rate with pacat for the SINK works fine
though. This is the command I used:
pacat -r --latency-msec=100 -d alsa_input.pci-0000_01_00.0.iec958-stereo
| pacat -p --latency-msec=100 -d
alsa_output.usb-M-AUDIO_M-Track_Hub-00.analog-stereo --rate=48000
Is this a general bug? Is there a way to change the sample rate for the
sink itself within the loopback module? I am still wondering why this
happens, as I can capture any other input without changing the sink
sample rate.
If i set the source to 48000 and the sink to 44100 it does not work. I
have no idea why. Any ideas?
Did you check what sample rates are really set for the sink/source
with "pactl list sinks" and "pactl list sources"? What you are setting
on the command line are in fact sample rates for the streams, not
for sink/source itself. There are several places where re-samplers
are used within PA, so that the rate of the stream need not match
the actual sample rate of the device.
Also, if the sink/source is busy (RUNNING or IDLE), PA will refuse to
change the sample rate. So ensure the source is SUSPENDED before
trying to set it to 48kHz.
I don't see a bug yet, apart from the fact that the TOS link apparently
passes on the sample rate of the connected device and ignores the
rate set for the source in PA. But because there is no easy way to
determine the rate of an incoming stream, I cannot see how this
could be fixed in PA.
In general (because of re-sampling) it should work if the source is
set to 48kHz and the sink is at 44.1kHz. In your pacat example
however you are connecting two independent streams, so if the
first stream is running on 48kHz and you tell the second stream
to interpret the data as being 44.1kHz, it cannot work.
The first (recording) stream always uses 48kHz regardless what you
specify because it takes the samples from the TOS link "as is", so if
you tell the second stream (playback) to interpret the data as 48kHz
it will work. This is why you have to set the sink side to 48kHz in your
pacat example.
The problem is not what the source is receiving - we know now it
is always 48kHz - but to tell PA the right sample rate. As long as PA
thinks the source is at 44.1kHz while samples are coming in at 48kHz,
things will break.
What you could do is just swap the alternate and default sample rates.
This allows that 44.1kHz content can still be played without re-sampling,
while the default is 48kHz.
_______________________________________________
pulseaudio-discuss mailing list
[email protected]
https://lists.freedesktop.org/mailman/listinfo/pulseaudio-discuss