muhlenpfordt created this revision. muhlenpfordt added a reviewer: Plasma. Restricted Application added a project: Plasma. Restricted Application added a subscriber: plasma-devel. muhlenpfordt requested review of this revision.
REVISION SUMMARY When the Timer plasmoid is paused an opacity animation is used to signal this state. After resuming, restarting or resetting the timer the current opacity value is not reset which leads to nearly invisible and hard to read timer digits sometimes. This patch sets the opacity to 100% on timer (re)start and reset. BUG: 396497 TEST PLAN - Start Timer plasmoid with e.g. 5 minutes countdown - Pause Timer by click - When opacity is low - Resume by click or - Restart with predefined time or - Reset timer - Opacity of running timer should always reset to 100% REPOSITORY R114 Plasma Addons BRANCH fix-opacity (branched from master) REVISION DETAIL https://phabricator.kde.org/D14701 AFFECTED FILES applets/timer/package/contents/ui/main.qml To: muhlenpfordt, #plasma Cc: plasma-devel, ragreen, Pitel, ZrenBot, lesliezhai, ali-mohamed, jensreuterberg, abetts, sebas, apol, mart