graesslin added a comment.
I fear this broke some functionality of KRunner. It is important to be a dock window! Otherwise KRunner might not be able to go above fullscreen windows and won't be on all desktops. Also without being a PlasmaSurface the manual positioning cannot work. If it works for you, I fear it is pure chance. REPOSITORY R120 Plasma Workspace REVISION DETAIL https://phabricator.kde.org/D10197 To: apol, #plasma, davidedmundson Cc: graesslin, broulik, ngraham, davidedmundson, plasma-devel, ZrenBot, progwolff, lesliezhai, ali-mohamed, jensreuterberg, abetts, sebas, apol, mart