This is an automatically generated e-mail. To reply, visit:
http://git.reviewboard.kde.org/r/104226/#review12560
-----------------------------------------------------------


I just applied it to latest master and found a few usability issues:
* The settings dialog that contains all the configs is way too small
* The slider "grab" is 10 pixels to the left, some QML component issue
And the showstopper issue is:
There is no easy way to see the battery percentage. The overlay number is no 
longer available. And also there is no tooltip, i.e. hovering the plasmoid also 
does nothing. You _always_ have to click the battery plasmoid to see the exact 
percentage.
The tooltip thing seems to be a general QML plasmoid issue, the new devicec 
notifier also lacks one.

- Kai Uwe Broulik


On April 3, 2012, 5:12 a.m., Viranch Mehta wrote:
> 
> -----------------------------------------------------------
> This is an automatically generated e-mail. To reply, visit:
> http://git.reviewboard.kde.org/r/104226/
> -----------------------------------------------------------
> 
> (Updated April 3, 2012, 5:12 a.m.)
> 
> 
> Review request for Plasma.
> 
> 
> Description
> -------
> 
> I fixed the QML battery monitor to be fairly usable and this diff merges it 
> to master.
> 
> 
> Diffs
> -----
> 
>   plasma/generic/applets/CMakeLists.txt 2dedcb2 
>   plasma/generic/applets/batterymonitor/CMakeLists.txt PRE-CREATION 
>   plasma/generic/applets/batterymonitor/Messages.sh PRE-CREATION 
>   plasma/generic/applets/batterymonitor/README.txt PRE-CREATION 
>   plasma/generic/applets/batterymonitor/battery-oxygen-inkscape.svgz 
> PRE-CREATION 
>   plasma/generic/applets/batterymonitor/battery-oxygen.svgz PRE-CREATION 
>   plasma/generic/applets/batterymonitor/contents/config/main.xml PRE-CREATION 
>   plasma/generic/applets/batterymonitor/contents/ui/IconButton.qml 
> PRE-CREATION 
>   plasma/generic/applets/batterymonitor/contents/ui/PopupDialog.qml 
> PRE-CREATION 
>   plasma/generic/applets/batterymonitor/contents/ui/batterymonitor.qml 
> PRE-CREATION 
>   plasma/generic/applets/batterymonitor/contents/ui/config.ui PRE-CREATION 
>   plasma/generic/applets/batterymonitor/metadata.desktop PRE-CREATION 
>   plasma/generic/dataengines/powermanagement/powermanagementengine.h 20642c2 
>   plasma/generic/dataengines/powermanagement/powermanagementengine.cpp 
> 5572fcb 
>   plasma/generic/dataengines/powermanagement/powermanagementjob.h 2c32015 
>   plasma/generic/dataengines/powermanagement/powermanagementjob.cpp e205bb0 
>   
> plasma/generic/dataengines/powermanagement/powermanagementservice.operations 
> ad1301f 
> 
> Diff: http://git.reviewboard.kde.org/r/104226/diff/
> 
> 
> Testing
> -------
> 
> Applet and dataengine both tested and work fine.
> 
> 
> Screenshots
> -----------
> 
> with top right graphic in the popup
>   http://git.reviewboard.kde.org/r/104226/s/487/
> applet on the workspace
>   http://git.reviewboard.kde.org/r/104226/s/503/
> 
> 
> Thanks,
> 
> Viranch Mehta
> 
>

_______________________________________________
Plasma-devel mailing list
Plasma-devel@kde.org
https://mail.kde.org/mailman/listinfo/plasma-devel

Reply via email to