Missatge de Ondřej Kuzník <[email protected]> del dia dt., 30 de gen.
2024 a les 16:19:

> are you running with syncprov-reloadhint by any chance? It's just a
> warning that syncprov might consider using the attribute but it's not
> defined. I've just moved the check to syncprov-nopresent[0] which
> doesn't really have any uses without an accesslog DB being around.


You're right, I realized that I had the Reloadhint setting to true. Once
disabled my issue has gone. Thanks much for pointing.

No need for accesslog if you're doing plain syncrepl.
>

Well, I wanted to use delta-syncrepl, but the small size and changes on my
DIT didn't require it, so I kept as is


> AFAIK people don't usually do deltasync for cn=config).
>

Make sense.

This bring me a new question (which I think I already get replied or found
in some place but now I'm unable to find)

On a multiple replica setup (N-way Multimaster) setup, how does the server
identify itself in the multiple olcSyncrepl attributes to avoid trying to
replicate against itself ?

Thanks much

Reply via email to