--On Tuesday, November 30, 2010 8:33 PM +0100 Dieter Kluenter
<[email protected]> wrote:
On the master, in the accesslog database section, you are missing the
syncprov overlay:
overlay syncprov
syncprov-nopresent TRUE
syncprov-reloadhint TRUE
This I realised after running test043 too, but I wonder whether this
is required at all, or is this just lack of documentation?
It is absolutely required, as the accesslog database is providing
information to the syncrepl client, thus it must have the syncprov overlay
in place.
--Quanah
--