This is a not too rare problem with current SSDs
(The manufacturers haven't recognised the importance of individual WWNs)

Even my distributor (winkom) specialized in enterprise SSD listed SSD with
individual WWN only after my request.

What you can do:
disable multipath

What you should do:
do not use them together with controllers that identify disks based on WWN
(ex. LSI SAS2 controller in IT mode) or you may not be able to identify in case of problems.


Gea
napp-it.org


neat problem.
generally the wwn is stamped on the drive. are they all marked with the same 
wwn?

who makes the drives? ocz? sandisk?

Sent from Jasons' hand held

On Mar 21, 2013, at 6:13 AM, "Schweiss, Chip" <[email protected]> wrote:

I have four 480GB SSDs I'm trying to re-add to my pool as L2ARC.   They
were all connected internally on the server, but now I have a dedicated SAS
JBOD for the 2 1/2 SSDs in the system.   The JBOD is a SuperMicro 2U with
LSI SAS2X36 expander.

The SSDs are are all showing up as a single device: c11t0000120000000000d0s0

They are incorrectly identified as the same device by the multipathadm:

mutipathadm list lu:

        /dev/rdsk/c11t0000120000000000d0s2
                Total Path Count: 4
                Operational Path Count: 4

Not sure where napp-it gets its information for it's controller view but
this is how it reports them:

c14::w5003048001d91b4e,0   connected   configured   unknown   Client
Device: /dev/dsk/c11t0000120000000000d0s0(sd75) disk-path n /devices/pci@0
,0/pci8086,340e@7/pci1000,30d0@0/iport@f000:scsi::w5003048001d91b4e,0
c14::w5003048001d91b4f,0   connected   configured   unknown   Client
Device: /dev/dsk/c11t0000120000000000d0s0(sd75) disk-path n /devices/pci@0
,0/pci8086,340e@7/pci1000,30d0@0/iport@f000:scsi::w5003048001d91b4f,0
c14::w5003048001d91b5a,0   connected   configured   unknown   Client
Device: /dev/dsk/c11t0000120000000000d0s0(sd75) disk-path n /devices/pci@0
,0/pci8086,340e@7/pci1000,30d0@0/iport@f000:scsi::w5003048001d91b5a,0
c14::w5003048001d91b5b,0   connected   configured   unknown   Client
Device: /dev/dsk/c11t0000120000000000d0s0(sd75) disk-path n /devices/pci@0
,0/pci8086,340e@7/pci1000,30d0@0/iport@f000:scsi::w5003048001d91b5b,0

How do I break this and get OI to see these as 4 independent devices?

Thank you,
-Chip
_______________________________________________
OpenIndiana-discuss mailing list
[email protected]
http://openindiana.org/mailman/listinfo/openindiana-discuss
_______________________________________________
OpenIndiana-discuss mailing list
[email protected]
http://openindiana.org/mailman/listinfo/openindiana-discuss



_______________________________________________
OpenIndiana-discuss mailing list
[email protected]
http://openindiana.org/mailman/listinfo/openindiana-discuss

Reply via email to