I am not sure that I can disable flow control since no switch is present. Is it 
turned on in the host by default?


-----Original Message-----
From: Sašo Kiselkov [mailto:[email protected]] 
Sent: Saturday, February 16, 2013 6:05 PM
To: [email protected]
Subject: Re: [OpenIndiana-discuss] ISCSI SSD Performance

On 02/16/2013 11:58 PM, Sašo Kiselkov wrote:
> On 02/16/2013 11:37 PM, Ian Collins wrote:
>> Have you tried the connecting to the volume form another IO host to 
>> eliminate vmware as the cause?
> 
> Second that.
> 
> The 9k MTU might also be hitting some NIC driver bugs - non-standard 
> settings can, at times. Since the difference is only in the storage -> 
> VMware direction, I suspect there may be some trouble there (perhaps 
> VMware not being entirely okay with how OI is handling the 9k MTUs?).

One more thing comes to mind: if all else fails, try to disable flow control. 
Sometimes it can mess up throughput, if the receiving NIC erratically sends too 
many TX frames - can be a driver issue in VMware, though this is quite a long 
stretch.

Anyway, right now I suspect VMware might be the culprit here. The number of 
kittens that have to be slaughtered to get such a high packet switching 
performance from VMs to storage is astounding.

Cheers,
--
Saso