Dan Swartzendruber wrote:
> I'm not understanding your problem.  If you add a 3rd temporary disk, wait
> for it to resilver, then replace c1t5d0, let the new disk resilver, then
> detach the temporary disk, you will never have less than 2 up to date disks
> in the mirror. What am I missing?
> 

Dan,

you're right, I was trying to find a way to "move" the new disk in the failing
disk bay instead of simply replacing the failing one :)

Thanks for the advice!

Maurilio.

-- 