You might want to look at the a_svct and %w / %b times on iostat -xn 1 ; The a_svct should be very low on the intel SSD's; preferably less than one. You might also want to look with only one of the SSD's working at a time; either ARC or ZIL.
Offhand; this sounds a bit odd, especially since a single set of 12 disks in raidz2 isn't particularly fast. If your F40 is actually honoring cache flushes as expected; it would not actually have very fast random IO due to being MLC drive; the X25-e may still be faster. Perhaps putting one or 2 of the F40's as cache; and one/two of the x25-e's as logs might work better? If you have the internal slots and hardware to spare; you can add multiple log/cache devices to a single pool. -Lucas Van Tol > Date: Fri, 24 Jun 2011 18:19:23 -0700 > From: [email protected] > To: [email protected] > Subject: [OpenIndiana-discuss] write speeds faster with no ZIL and L2ARC > > Hi, > > *Problem:* > write speeds are faster when no L2ARC or ZIL is configured. > > *Our current setup:* > We are currently running OpenIndiana b148 (upgraded from b134.) Supermicro > X8DTH-i/6/iF/6F, single Xeon E5504, 24GB ram. A single, main storage pool is > running pool version 28, populated with 12 WD RE 7200rpm SATA disks in a > RAIDZ2. This pool has two 32GB Intel X25-E SSD's for ZIL and L2ARC connected > directly to SATA ports on the motherboard. The entire system has been in > operation for about one year with minimal issues. About a week ago we > started seeing slow write performance so troubleshooting began. > > *What we have done so far / what we know:* > We removed the ZIL and L2ARC SSD's from the server, zpool remove tank c6t1d0 > c6t0d0 > and connected them to a windows machine and ran Intel SSD > Tool<http://downloadcenter.intel.com/Detail_Desc.aspx?agr=Y&DwnldID=18455>on > them. (a windows only application) > > Using Intel SSD Toolbox 2.0.2.000, we see the following values; > > 09 Power-On Hours Count: > ZIL: Raw: 6783 > L2ARC: Raw: 8562 > > E9 Media Wearout Indicator: > ZIL: Raw: 0 Normalized: 99 Threshold: 0 > L2ARC: Raw: 0 Normalized: 99 Threshold: 0 > > E1 Host Writes > ZIL: Raw: 47 TB Normalized: 200 Threshold: 0 > L2ARC: Raw: 67 TB Normalized: 199 Threshold: 0 > > Looking at this, we can only conclude that either; > 1) Intel X25-E drives have no "wear" even after ~50-60 TB of writes > 2) The wearout indicator is broken and unreliable. > > Here are some write tests we have performed using rsync to transfer a 3.5GB > ISO file from my workstation over Gigabit Ethernet to a file system in this > server. All tests go to the same file system unless otherwise noted, and > after each test the already transfered bits were removed from the server. > > TRANSFER AMOUNT TIME TAKEN NOTES/CONDITIONS > 1GB 6:00min > tank/shares/sw which has (compression=gzip-6) X25-E ZIL and L2ARC are > present > 1GB 50sec > rpool/home/chris (two sata disks in mirror, no compression) > 1GB 3:30 > tank pool without L2ARC > 1GB 1:30 > tank pool no L2ARC and no ZIL > 500MB 4:30 > tank pool, brand new ZIL, Corsair F40GB2 (40GB) > 500MB 3:50 > tank pool, new ZIL and new L2ARC, both Corsair F40GB2 > 800MB 6:00 > tank pool, new L2ARC and new ZIL have now had ~3 hours to "warm up", > l2arcstat went from 47MB to 22GB > > So our problem is that even with brand new SSD's, that have MUCH higher > maximum write speeds then are "old" SSD's, transfers happen to the storage > pool quicker *without* configured log and cache devices, then when they are > being used. FWIW, looking at iostat -exn while running one of the rsync > tests above, the time things are taking seem to match up on the kw/s column. > > Can anyone provide insight to this slow write speed situation when ZIL and > L2ARC is present? > _______________________________________________ > OpenIndiana-discuss mailing list > [email protected] > http://openindiana.org/mailman/listinfo/openindiana-discuss _______________________________________________ OpenIndiana-discuss mailing list [email protected] http://openindiana.org/mailman/listinfo/openindiana-discuss