Dotan Barak wrote: > Hi Moni. > > I tried to use the mthca module parameter: for example i tried to change > the number of QPs. > > I got several failures when i used the HCA 25204: > * sometimes i got the following error message (when using big values, > for example 512K QPs): > ib_mthca: 0000:0c: INIT_HCA command failed aborting. > ib_mthca: probe of 0000:0c: failed with error -16 > * when i tried to use small amount of QPs (1024) the machine just hanged > and i noticed a kernel oops message on the console > > > Did you verify the HCA profile module parameter feature? > Is there is any known limitation for the values that should be used? > (for example: only values which are power of two) > > > thanks > Dotan >
Hi Dotan, I verified the profile feature up to the level of successful modprobe. I am working now to look into your report. thanks _______________________________________________ openib-general mailing list [email protected] http://openib.org/mailman/listinfo/openib-general To unsubscribe, please visit http://openib.org/mailman/listinfo/openib-general