Hello Luca,

 > How did you configure sflow in your foundry?
I've configured the rate to 1 on all ports. After doing this, I can see 
that captured informations are better accurate but not 100%. For 
example, if I transfers 100 MB now, I will see around 90 MB. I think I 
cannot do better than that because it use sampling as you said.

Gerhard,

Luca Deri wrote:
> Gerhard
> sflow uses sampling. hence if you send let's say 100 you will see 1
> using sflow. How did you configure sflow in your foundry?
>
> Luca
>
> On Oct 31, 2008, at 7:33 PM, Gerhard Mourani wrote:
>
>   
>> Hello List,
>>
>> I've activated the sFlow plugin into my ntop version 3.3.8 to capture
>> and display sFlow data coming from my "Foundry Network FastIron Edge
>> 9604" model. If I check inside the plugin page of sFlow about 'sFlow
>> Interface Statistics' everything are correct and reported data
>> transfers
>> for 'Administrative' or 'Operational' status are ok. But now my
>> problem
>> is when I check inside the ntop web interface and especially about
>> collected data, here the problem is that returned informations about
>> amount of data are wrong, I mean the amount of data doesn't correspond
>> to what have really been transfered. So for example if I transfer 135
>> MBytes I can only see 295.0 KBytes in ntop. Someone know how to fix
>> this?
>>
>> Thanks for your helps,
>> Gerhard,
>> _______________________________________________
>> Ntop mailing list
>> [email protected]
>> http://listgateway.unipi.it/mailman/listinfo/ntop
>>     
>
> _______________________________________________
> Ntop mailing list
> [email protected]
> http://listgateway.unipi.it/mailman/listinfo/ntop
>   
_______________________________________________
Ntop mailing list
[email protected]
http://listgateway.unipi.it/mailman/listinfo/ntop

Reply via email to