E-Switch capabilities should be queried only if E-Switch flow table
is supported and not only when vport group manager.
Fixes: d6666753c6e8 ("net/mlx5: E-Switch, Introduce HCA cap and E-Switch vport
context")
Signed-off-by: Saeed Mahameed <[email protected]>
---
drivers/net/ethernet/mellanox/mlx5/core/fw.c | 2 +-
1 files changed, 1 insertions(+), 1 deletions(-)
diff --git a/drivers/net/ethernet/mellanox/mlx5/core/fw.c
b/drivers/net/ethernet/mellanox/mlx5/core/fw.c
index 1c9f9a5..aa1ab47 100644
--- a/drivers/net/ethernet/mellanox/mlx5/core/fw.c
+++ b/drivers/net/ethernet/mellanox/mlx5/core/fw.c
@@ -173,7 +173,7 @@ int mlx5_query_hca_caps(struct mlx5_core_dev *dev)
return err;
}
- if (MLX5_CAP_GEN(dev, vport_group_manager)) {
+ if (MLX5_CAP_GEN(dev, eswitch_flow_table)) {
err = mlx5_core_get_caps(dev, MLX5_CAP_ESWITCH,
HCA_CAP_OPMOD_GET_CUR);
if (err)
--
1.7.1
--
To unsubscribe from this list: send the line "unsubscribe netdev" in
the body of a message to [email protected]
More majordomo info at http://vger.kernel.org/majordomo-info.html