The current bcm63xx_enet driver doesn't asign the internal phy IRQ. As a
result of this it works in polling mode.

Fix it using the phy_device structure to assign the platform IRQ.

Tested under a BCM6348 board. Kernel dmesg before the patch:
   Broadcom BCM63XX (1) bcm63xx_enet-0:01: attached PHY driver [Broadcom
              BCM63XX (1)] (mii_bus:phy_addr=bcm63xx_enet-0:01, irq=POLL)

After the patch:
   Broadcom BCM63XX (1) bcm63xx_enet-0:01: attached PHY driver [Broadcom
              BCM63XX (1)] (mii_bus:phy_addr=bcm63xx_enet-0:01, irq=17)

Pluging and uplugging the ethernet cable now generates interrupts and the
PHY goes up and down as expected.

Signed-off-by: Daniel González Cabanelas <dgcb...@gmail.com>
---
 drivers/net/ethernet/broadcom/bcm63xx_enet.c | 7 +++++++
 1 file changed, 7 insertions(+)

diff --git a/drivers/net/ethernet/broadcom/bcm63xx_enet.c 
b/drivers/net/ethernet/broadcom/bcm63xx_enet.c
index fd876721316..0dad527abb9 100644
--- a/drivers/net/ethernet/broadcom/bcm63xx_enet.c
+++ b/drivers/net/ethernet/broadcom/bcm63xx_enet.c
@@ -1819,7 +1819,14 @@ static int bcm_enet_probe(struct platform_device *pdev)
                bus->phy_mask = ~(1 << priv->phy_id);
 
                if (priv->has_phy_interrupt)
+                       phydev = mdiobus_get_phy(bus, priv->phy_id);
+                       if (!phydev) {
+                               dev_err(&dev->dev, "no PHY found\n");
+                               goto out_unregister_mdio;
+                       }
+
                        bus->irq[priv->phy_id] = priv->phy_interrupt;
+                       phydev->irq = priv->phy_interrupt;
 
                ret = mdiobus_register(bus);
                if (ret) {
-- 
2.30.1