Currently the PF will only set a trusted VF as the default VSI when it
requests FLAG_VF_UNICAST_PROMISC over VIRTCHNL. However, when
FLAG_VF_MULTICAST_PROMISC is set it's expected that the trusted VF will
see multicast packets that don't have a matching destination MAC in the
devices internal switch. Fix this by setting the trusted VF as the
default VSI if either FLAG_VF_UNICAST_PROMISC or
FLAG_VF_MULTICAST_PROMISC is set.

Fixes: 01b5e89aab49 ("ice: Add VF promiscuous support")
Signed-off-by: Brett Creeley <brett.cree...@intel.com>
Tested-by: Tony Brelinski <tonyx.brelin...@intel.com>
Signed-off-by: Tony Nguyen <anthony.l.ngu...@intel.com>
---
 drivers/net/ethernet/intel/ice/ice_virtchnl_pf.c | 2 +-
 1 file changed, 1 insertion(+), 1 deletion(-)

diff --git a/drivers/net/ethernet/intel/ice/ice_virtchnl_pf.c 
b/drivers/net/ethernet/intel/ice/ice_virtchnl_pf.c
index bf5fd812ea0e..07fae37a78be 100644
--- a/drivers/net/ethernet/intel/ice/ice_virtchnl_pf.c
+++ b/drivers/net/ethernet/intel/ice/ice_virtchnl_pf.c
@@ -2420,7 +2420,7 @@ static int ice_vc_cfg_promiscuous_mode_msg(struct ice_vf 
*vf, u8 *msg)
        }
 
        if (!test_bit(ICE_FLAG_VF_TRUE_PROMISC_ENA, pf->flags)) {
-               bool set_dflt_vsi = !!(info->flags & FLAG_VF_UNICAST_PROMISC);
+               bool set_dflt_vsi = alluni || allmulti;
 
                if (set_dflt_vsi && !ice_is_dflt_vsi_in_use(pf->first_sw))
                        /* only attempt to set the default forwarding VSI if
-- 