From: Florian Fainelli <f.faine...@gmail.com>
Date: Fri, 11 Sep 2020 11:28:27 -0700

> 
> 
> On 9/10/2020 9:19 PM, Florian Fainelli wrote:
>> Update the B53 driver to support VLANs while not filtering. This
>> requires us to enable VLAN globally within the switch upon driver
>> initial configuration (dev->vlan_enabled).
>> We also need to remove the code that dealt with PVID re-configuration
>> in
>> b53_vlan_filtering() since that function worked under the assumption
>> that it would only be called to make a bridge VLAN filtering, or not
>> filtering, and we would attempt to move the port's PVID accordingly.
>> Now that VLANs are programmed all the time, even in the case of a
>> non-VLAN filtering bridge, we would be programming a default_pvid for
>> the bridged switch ports.
>> Signed-off-by: Florian Fainelli <f.faine...@gmail.com>
> 
> David, Jakub, please hold off applying this just yet, Vladimir has
> submitted another patch for testing that would be IMHO a better way to
> deal with DSA switches that have an egress tagged
> default_pvid. Depending on the outcome of that patch, I will resubmit
> this one or request that you apply it.

Ok.

Reply via email to