The phy_reset_after_clk_enable() does a PHY reset, which means the PHY
loses its register settings. The fec_enet_mii_probe() starts the PHY
and does the necessary calls to configure the PHY via PHY framework,
and loads the correct register settings into the PHY. Therefore,
fec_enet_mii_probe() should be called only after the PHY has been
reset, not before as it is now.
Fixes: 1b0a83ac04e3 ("net: fec: add phy_reset_after_clk_enable() support")
Signed-off-by: Marek Vasut <[email protected]>
Cc: Christoph Niedermaier <[email protected]>
Cc: David S. Miller <[email protected]>
Cc: NXP Linux Team <[email protected]>
Cc: Richard Leitner <[email protected]>
Cc: Shawn Guo <[email protected]>
---
drivers/net/ethernet/freescale/fec_main.c | 10 +++++-----
1 file changed, 5 insertions(+), 5 deletions(-)
diff --git a/drivers/net/ethernet/freescale/fec_main.c
b/drivers/net/ethernet/freescale/fec_main.c
index fb37816a74db..23abe7f6cad0 100644
--- a/drivers/net/ethernet/freescale/fec_main.c
+++ b/drivers/net/ethernet/freescale/fec_main.c
@@ -2984,17 +2984,17 @@ fec_enet_open(struct net_device *ndev)
/* Init MAC prior to mii bus probe */
fec_restart(ndev);
- /* Probe and connect to PHY when open the interface */
- ret = fec_enet_mii_probe(ndev);
- if (ret)
- goto err_enet_mii_probe;
-
/* Call phy_reset_after_clk_enable() again if it failed during
* phy_reset_after_clk_enable() before because the PHY wasn't probed.
*/
if (reset_again)
phy_reset_after_clk_enable(ndev->phydev);
+ /* Probe and connect to PHY when open the interface */
+ ret = fec_enet_mii_probe(ndev);
+ if (ret)
+ goto err_enet_mii_probe;
+
if (fep->quirks & FEC_QUIRK_ERR006687)
imx6q_cpuidle_fec_irqs_used();
--
2.28.0