On 8/31/20 2:07 PM, Jakub Kicinski wrote:
On Mon, 31 Aug 2020 11:58:10 -0500 Thomas Falcon wrote:
Include documentation for existing ibmvnic sysfs files,
currently only for "failover," which is used to swap
the active hardware port to a backup port in redundant
backing hardware or failover configurations.

Signed-off-by: Thomas Falcon <tlfal...@linux.ibm.com>
---
  Documentation/ABI/testing/sysfs-driver-ibmvnic | 14 ++++++++++++++
  1 file changed, 14 insertions(+)
  create mode 100644 Documentation/ABI/testing/sysfs-driver-ibmvnic

diff --git a/Documentation/ABI/testing/sysfs-driver-ibmvnic 
b/Documentation/ABI/testing/sysfs-driver-ibmvnic
new file mode 100644
index 0000000..7fa2920
--- /dev/null
+++ b/Documentation/ABI/testing/sysfs-driver-ibmvnic
@@ -0,0 +1,14 @@
+What:          /sys/devices/vio/<our device>/failover
+Date:          June 2017
+KernelVersion: 4.13
+Contact:       linuxppc-...@lists.ozlabs.org
+Description:   If the ibmvnic device has been configured with redundant
+               physical NIC ports, the user may write "1" to the failover
+               file to trigger a device failover, which will reset the
+               ibmvnic device and swap to a backup physical port. If no
+               redundant physical port has been configured for the device,
+               the device will not reset and -EINVAL is returned. If anything
+               other than "1" is written to the file, -EINVAL will also be
+               returned.
+Users:         Any users of the ibmvnic driver which use redundant hardware
+               configurations.
Could you elaborate what the failover thing is? Is it what net_failover
does or something opposite? (you say "backup physical port" which
sounds like physical port is a backup.. perhaps some IBM nomenclature
there worth clarifying?)

Hi Jakub,

When creating a SRIOV VNIC device on a Power system, the user will specify one or more ports to use from physical NIC's available to the Power Hypervisor. These aren't visible to the Linux OS. In a failover configuration, the VNIC will have one active port and at least one other port in backup or standby mode. It's similar to the bonding driver's active-backup mode. If the hypervisor detects a problem with the active port, it will swap in the backup port and send a signal to the VNIC driver that it should reset, which is needed to activate the new port. There is also a mechanism through which the driver can force this operation in case the hypervisor does not detect an issue with the active port. This mechanism can be triggered by an administrator or with userspace tools through the 'failover' device file in sysfs.

Tom