From: Andrew Lunn <and...@lunn.ch>
Date: Sun, 21 Jul 2019 18:50:08 +0200

> The RX power read from the SFP uses units of 0.1uW. This must be
> scaled to units of uW for HWMON. This requires a divide by 10, not the
> current 100.
> 
> With this change in place, sensors(1) and ethtool -m agree:
> 
> sff2-isa-0000
> Adapter: ISA adapter
> in0:          +3.23 V
> temp1:        +33.1 C
> power1:      270.00 uW
> power2:      200.00 uW
> curr1:        +0.01 A
> 
>         Laser output power                        : 0.2743 mW / -5.62 dBm
>         Receiver signal average optical power     : 0.2014 mW / -6.96 dBm
> 
> Reported-by: chris.he...@zii.aero
> Signed-off-by: Andrew Lunn <and...@lunn.ch>
> Fixes: 1323061a018a ("net: phy: sfp: Add HWMON support for module sensors")

Applied and queued up for -stable, thanks Andrew.

Reply via email to