During probe we clear vNIC configuration in case the device
wasn't closed cleanly by previous driver.  Move that code
before netdev init, so netdev init can already try to apply
its config parameters.

Signed-off-by: Jakub Kicinski <jakub.kicin...@netronome.com>
Reviewed-by: Dirk van der Merwe <dirk.vanderme...@netronome.com>
---
 drivers/net/ethernet/netronome/nfp/nfp_net_common.c | 6 +++---
 1 file changed, 3 insertions(+), 3 deletions(-)

diff --git a/drivers/net/ethernet/netronome/nfp/nfp_net_common.c 
b/drivers/net/ethernet/netronome/nfp/nfp_net_common.c
index ab84a6c1ce66..e4be04cdef30 100644
--- a/drivers/net/ethernet/netronome/nfp/nfp_net_common.c
+++ b/drivers/net/ethernet/netronome/nfp/nfp_net_common.c
@@ -3986,9 +3986,6 @@ int nfp_net_init(struct nfp_net *nn)
                nn->dp.ctrl |= NFP_NET_CFG_CTRL_IRQMOD;
        }
 
-       if (nn->dp.netdev)
-               nfp_net_netdev_init(nn);
-
        /* Stash the re-configuration queue away.  First odd queue in TX Bar */
        nn->qcp_cfg = nn->tx_bar + NFP_QCP_QUEUE_ADDR_SZ;
 
@@ -4001,6 +3998,9 @@ int nfp_net_init(struct nfp_net *nn)
        if (err)
                return err;
 
+       if (nn->dp.netdev)
+               nfp_net_netdev_init(nn);
+
        nfp_net_vecs_init(nn);
 
        if (!nn->dp.netdev)
-- 
2.21.0