From: Marco Felsch <m.fel...@pengutronix.de>
Date: Tue, 15 May 2018 10:18:56 +0200

> From: Markus Niebel <markus.nie...@tqs.de>
> 
> The micrel KSZ9031 phy has a optional clock pin (CLK125_NDO) which can be
> used as reference clock for the MAC unit. The clock signal must meet the
> RGMII requirements to ensure the correct data transmission between the
> MAC and the PHY. The KSZ9031 phy does not fulfill the duty cycle
> requirement if the phy is configured as slave. For a complete
> describtion look at the errata sheets: DS80000691D or DS80000692D.
> 
> The errata sheet recommends to force the phy into master mode whenever
> there is a 1000Base-T link-up as work around. Only set the
> "micrel,force-master" property if you use the phy reference clock provided
> by CLK125_NDO pin as MAC reference clock in your application.
> 
> Attenation, this workaround is only usable if the link partner can
> be configured to slave mode for 1000Base-T.
> 
> Signed-off-by: Markus Niebel <markus.nie...@tqs.de>
> [m.fel...@pengutronix.de: fix dt-binding documentation]
> [m.fel...@pengutronix.de: use already existing result var for read/write]
> [m.fel...@pengutronix.de: add error handling]
> [m.fel...@pengutronix.de: add more comments]
> Signed-off-by: Marco Felsch <m.fel...@pengutronix.de>

Applied, thank you.

Reply via email to