> +static int dp83811_config_aneg(struct phy_device *phydev)
> +{
> +     int err;
> +     int value;
> +
> +     value = phy_read(phydev, MII_DP83811_SGMII_CTRL);
> +     if (phydev->autoneg == AUTONEG_ENABLE) {
> +             err = phy_write(phydev, MII_DP83811_SGMII_CTRL,
> +                             (DP83811_SGMII_AUTO_NEG_EN | value));
> +             if (err < 0)
> +                     return err;
> +     } else {
> +             err = phy_write(phydev, MII_DP83811_SGMII_CTRL,
> +                             (~DP83811_SGMII_AUTO_NEG_EN & value));
> +             if (err < 0)
> +                     return err;
> +     }
> +

Hi Dan

You say SGMII is unreliable on one of these devices. Should you check
phydev->interface before enabling SGMII autoneg?

> +     return genphy_config_aneg(phydev);
> +}
> +
> +static int dp83811_config_init(struct phy_device *phydev)
> +{
> +     int err;
> +     int value;
> +
> +     err = genphy_config_init(phydev);
> +     if (err < 0)
> +             return err;
> +
> +     if (phydev->interface == PHY_INTERFACE_MODE_SGMII) {
> +             value = phy_read(phydev, MII_DP83811_SGMII_CTRL);
> +             if (!(value & DP83811_SGMII_EN)) {
> +                     err = phy_write(phydev, MII_DP83811_SGMII_CTRL,
> +                                     (DP83811_SGMII_EN | value));
> +                     if (err < 0)
> +                             return err;
> +             } else {
> +                     err = phy_write(phydev, MII_DP83811_SGMII_CTRL,
> +                             (~DP83811_SGMII_EN & value));
> +                     if (err < 0)
> +                             return err;
> +             }

This looks to be a duplicate of dp83811_config_aneg()?

> +     }
> +
> +     value = DP83811_WOL_MAGIC_EN | DP83811_WOL_SECURE_ON | DP83811_WOL_EN;
> +
> +     return phy_write_mmd(phydev, DP83811_DEVADDR, MII_DP83811_WOL_CFG,
> +           value);
> +}
> +
> +static int dp83811_phy_reset(struct phy_device *phydev)
> +{
> +     int err;
> +
> +     err = phy_write(phydev, MII_DP83811_RESET_CTRL, DP83811_HW_RESET);
> +     if (err < 0)
> +             return err;
> +
> +     dp83811_config_init(phydev);

I don't think you need to initialize it here. phylib should call that
soon after the reset.

> +
> +     return 0;
> +}
> +

> +static struct phy_driver dp83811_driver[] = {
> +     {
> +             .phy_id = DP83TC811_PHY_ID,
> +             .phy_id_mask = 0xfffffff0,
> +             .name = "TI DP83TC811",
> +             .features = PHY_BASIC_FEATURES,
> +             .flags = PHY_HAS_INTERRUPT,
> +             .config_init = genphy_config_init,

????

        Andrew

Reply via email to