From: William Tu <u9012...@gmail.com>
Date: Thu,  1 Mar 2018 13:49:56 -0800

> Currently GRE sequence number can only be used in native tunnel mode.
> The first patch adds sequence number support for gre collect
> metadata mode, and the second patch tests it using BPF.
> 
> RFC2890 defines GRE sequence number to be specific to the traffic
> flow identified by the key.  However, this patch does not implement
> per-key seqno.  The sequence number is shared in the same tunnel
> device. That is, different tunnel keys using the same collect_md
> tunnel share single sequence number.
> 
> A new BFP uapi tunnel flag 'BPF_F_SEQ_NUMBER' is added.
> --
> v1->v2:
>   rename BPF_F_GRE_SEQ to BPF_F_SEQ_NUMBER suggested by Daniel

Series applied, thank you.

Reply via email to