From: Guillaume Nault <g.na...@alphalink.fr> Date: Wed, 10 Jan 2018 16:24:45 +0100
> ppp_dev_uninit(), which is the .ndo_uninit() handler of PPP devices, > needs to lock pn->all_ppp_mutex. Therefore we mustn't call > register_netdevice() with pn->all_ppp_mutex already locked, or we'd > deadlock in case register_netdevice() fails and calls .ndo_uninit(). > > Fortunately, we can unlock pn->all_ppp_mutex before calling > register_netdevice(). This lock protects pn->units_idr, which isn't > used in the device registration process. > > However, keeping pn->all_ppp_mutex locked during device registration > did ensure that no device in transient state would be published in > pn->units_idr. In practice, unlocking it before calling > register_netdevice() doesn't change this property: ppp_unit_register() > is called with 'ppp_mutex' locked and all searches done in > pn->units_idr hold this lock too. > > Fixes: 8cb775bc0a34 ("ppp: fix device unregistration upon netns deletion") > Reported-and-tested-by: syzbot+367889b9c9e279219...@syzkaller.appspotmail.com > Signed-off-by: Guillaume Nault <g.na...@alphalink.fr> Applied and queued up for -stable, thank you.