On Fri, Jun 2, 2017 at 11:54 AM, Eric Garver <e...@erig.me> wrote: > Since commit 9b4437a5b870 ("geneve: Unify LWT and netdev handling.") > when using COLLECT_METADATA geneve devices are created with too small of > a needed_headroom and too large of a max_mtu. This is because > ip_tunnel_info_af() is not valid with the device level info when using > COLLECT_METADATA and we mistakenly fall into the IPv4 case. > > For COLLECT_METADATA, always use the worst case of ipv6 since both > sockets are created. > > Fixes: 9b4437a5b870 ("geneve: Unify LWT and netdev handling.") > Signed-off-by: Eric Garver <e...@erig.me>
Acked-by: Pravin B Shelar <pshe...@ovn.org> Thanks.