On Fri, Jun 2, 2017 at 11:54 AM, Eric Garver <e...@erig.me> wrote:
> Since commit 9b4437a5b870 ("geneve: Unify LWT and netdev handling.")
> when using COLLECT_METADATA geneve devices are created with too small of
> a needed_headroom and too large of a max_mtu. This is because
> ip_tunnel_info_af() is not valid with the device level info when using
> COLLECT_METADATA and we mistakenly fall into the IPv4 case.
>
> For COLLECT_METADATA, always use the worst case of ipv6 since both
> sockets are created.
>
> Fixes: 9b4437a5b870 ("geneve: Unify LWT and netdev handling.")
> Signed-off-by: Eric Garver <e...@erig.me>

Acked-by: Pravin B Shelar <pshe...@ovn.org>

Thanks.

Reply via email to