On Tue, 16 May 2017, Wei Yongjun wrote: > From: Wei Yongjun <weiyongj...@huawei.com> > > In case of error, the function xenbus_read() returns ERR_PTR() and never > returns NULL. The NULL test in the return value check should be replaced > with IS_ERR(). > > Fixes: 71ebd71921e4 ("xen/9pfs: connect to the backend") > Signed-off-by: Wei Yongjun <weiyongj...@huawei.com>
Reviewed-by: Stefano Stabellini <sstabell...@kernel.org> Thank you! > --- > net/9p/trans_xen.c | 4 ++-- > 1 file changed, 2 insertions(+), 2 deletions(-) > > diff --git a/net/9p/trans_xen.c b/net/9p/trans_xen.c > index 71e8564..83fe487 100644 > --- a/net/9p/trans_xen.c > +++ b/net/9p/trans_xen.c > @@ -454,8 +454,8 @@ static int xen_9pfs_front_probe(struct xenbus_device *dev, > goto error_xenbus; > } > priv->tag = xenbus_read(xbt, dev->nodename, "tag", NULL); > - if (!priv->tag) { > - ret = -EINVAL; > + if (IS_ERR(priv->tag)) { > + ret = PTR_ERR(priv->tag); > goto error_xenbus; > } > ret = xenbus_transaction_end(xbt, 0); >